Projects
openEuler:Mainline
tomcat
_service:tar_scm:CVE-2019-0199-6.patch
Sign Up
Log In
Username
Password
Overview
Repositories
Revisions
Requests
Users
Attributes
Meta
File _service:tar_scm:CVE-2019-0199-6.patch of Package tomcat
--- tomcat/webapps/docs/config/http2.xml 2019/02/01 10:28:22 1852702 +++ tomcat/webapps/docs/config/http2.xml 2019/02/01 10:28:26 1852703 @@ -125,9 +125,9 @@ <attribute name="keepAliveTimeout" required="false"> <p>The time, in milliseconds, that Tomcat will wait between HTTP/2 frames - before closing the connection. Negative values will be treated as an - infinite timeout. If not specified, a default value of <code>-1</code> - will be used.</p> + when there is no active Stream before closing the connection. Negative + values will be treated as an infinite timeout. If not specified, a default + value of <code>20000</code> will be used.</p> </attribute> <attribute name="maxConcurrentStreamExecution" required="false"> @@ -192,7 +192,24 @@ <p>The time, in milliseconds, that Tomcat will wait for additional data when a partial HTTP/2 frame has been received. Negative values will be treated as an infinite timeout. If not specified, a default value of - <code>10000</code> will be used.</p> + <code>5000</code> will be used.</p> + </attribute> + + <attribute name="streamReadTimeout" required="false"> + <p>The time, in milliseconds, that Tomcat will wait for additional data + frames to arrive for the stream when an application is performing a + blocking I/O read and additional data is required. Negative values will be + treated as an infinite timeout. If not specified, a default value of + <code>20000</code> will be used.</p> + </attribute> + + <attribute name="streamWriteTimeout" required="false"> + <p>The time, in milliseconds, that Tomcat will wait for additional window + update frames to arrive for the stream and/or conenction when an + application is performing a blocking I/O write and the stream and/or + connection flow control window is too small for the write to complete. + Negative values will be treated as an infinite timeout. If not specified, + a default value of <code>20000</code> will be used.</p> </attribute> <attribute name="useSendfile" required="false"> @@ -204,7 +221,7 @@ <p>The time, in milliseconds, that Tomcat will wait to write additional data when an HTTP/2 frame has been partially written. Negative values will be treated as an infinite timeout. If not specified, a default value of - <code>10000</code> will be used.</p> + <code>5000</code> will be used.</p> </attribute> </attributes>
Locations
Projects
Search
Status Monitor
Help
Open Build Service
OBS Manuals
API Documentation
OBS Portal
Reporting a Bug
Contact
Mailing List
Forums
Chat (IRC)
Twitter
Open Build Service (OBS)
is an
openSUSE project
.
浙ICP备2022010568号-2